Skip to main navigation Skip to search Skip to main content

Performance of a Retrofitted Multicyclone for PM2.5 Emission Control

  • Sunway University
  • Universiti Teknologi Malaysia
  • AMR Environmental Sdn Bhd

Research output: Contribution to journal › Conference article › peer-review

Abstract

This paper presents on the performance of a retrofitted multicyclone system, which aims to increase the collection efficiency of PM2.5 (i.e. particulate size fraction ≤ 2.5 μm) emission. The multicyclone was retrofitted by extracting 15% and 20% of the total volumetric air flow rate at the dust hopper of the unit using an additional Induced Draft Fan. The total collection efficiency with and without the extraction was measured at various air volumetric flow rates and particulate mass inlet concentration. The results showed that there was a reduction of 12% to 54% depending on the inlet concentration of PM2.5 emission in the stack with compared to without extraction increasing the collection efficiency of the retrofitted multicyclone. The finding suggests that a simple technique of applying gas extraction at the dust hopper of a multicyclone as reported in this study able to increase the overall performance in fine particulate collection.

Original languageEnglish
Article number02011
JournalE3S Web of Conferences
Volume34
DOIs
Publication statusPublished - 19 Mar 2018
Externally publishedYes
Event1st International Conference on Civil and Environmental Engineering, CENVIRON 2017 - Penang, Malaysia
Duration: 28 Nov 2017 → 29 Nov 2017

Fingerprint

Dive into the research topics of 'Performance of a Retrofitted Multicyclone for PM2.5 Emission Control'. Together they form a unique fingerprint.

Cite this