N2 - The expansion of electric distribution system has resulted in an increasing iieed of fault current limiter in so as to limit fault currents to the, downstream protection devices as a means of improving power quality. Considerations in the use of fault current limiter are that it must be reliable in operation, compact and inexpensive. This paper presents a comprehensive performance evaluation on the use of soiid-state fault current limiters (FCL) in a distribution system. The FCL simulation model has been developed using the electromagnetic transient program PSCAD/EMTDC and a new control strategy for the FCL has been proposed for instantaneous dctection of over current. The FCL is evaluated in terms of its performance in limiting fauh current to the tolerable limit of the system, as well as the response of the FCL within a fraction of a cycle of about 2 ms. The effects of varying circuit parameters such as R, L, and C as part of the FCL device has been investigated. It has been noted that the inductive reactor, which is part of the FCL device, is suitable for limiting the fault current. The impact of induction motor loads on the FCL has also been analyzed. Simulation results show that the FCL is effective for reducing short circuit currents and also can be used to protect bus bars from voltage sag when the system is subjected to various types of faults.
AB - The expansion of electric distribution system has resulted in an increasing iieed of fault current limiter in so as to limit fault currents to the, downstream protection devices as a means of improving power quality. Considerations in the use of fault current limiter are that it must be reliable in operation, compact and inexpensive. This paper presents a comprehensive performance evaluation on the use of soiid-state fault current limiters (FCL) in a distribution system. The FCL simulation model has been developed using the electromagnetic transient program PSCAD/EMTDC and a new control strategy for the FCL has been proposed for instantaneous dctection of over current. The FCL is evaluated in terms of its performance in limiting fauh current to the tolerable limit of the system, as well as the response of the FCL within a fraction of a cycle of about 2 ms. The effects of varying circuit parameters such as R, L, and C as part of the FCL device has been investigated. It has been noted that the inductive reactor, which is part of the FCL device, is suitable for limiting the fault current. The impact of induction motor loads on the FCL has also been analyzed. Simulation results show that the FCL is effective for reducing short circuit currents and also can be used to protect bus bars from voltage sag when the system is subjected to various types of faults.
KW - Fault current limiter
KW - Power quality
UR - https://www.scopus.com/pages/publications/52349107459
U2 - 10.1109/SCORED.2003.1459700
DO - 10.1109/SCORED.2003.1459700
M3 - Conference contribution
AN - SCOPUS:52349107459
T3 - Student Conference on Research and Development: Networking the Future Mind in Convergence Technology, SCOReD 2003 - Proceedings
SP - 245
EP - 250
BT - Student Conference on Research and Development
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - Student Conference on Research and Development, SCOReD 2003
Y2 - 25 August 2003 through 26 August 2003
ER -