TY - GEN
T1 - CONDENSATION OF ATMOSPHERIC PRESSURE STEAM ON INTEGRAL-FIN TUBES – EFFECT OF FIN HEIGHT AND VAPOUR VELOCITY
AU - Namasivayam, S.
AU - Briggs, A.
N1 - Publisher Copyright:
© 2026, Begell House Inc. All rights reserved.
PY - 2006
Y1 - 2006
N2 - New experimental data are reported for forced-convection condensation of steam on a set of four single, copper, integral-fin tubes. All tubes had a fin root diameter of 12.7 mm. The fins were rectangular in cross section with fin spacing and thickness of 1.0 mm and 0.5 mm respectively and fin heights of 0.5, 0.9, 1.3 and 1.6 mm. A plain tube of outside diameter 12.7 mm was also tested. The tests were performed at a pressure slightly above atmospheric and covered vapour velocities between 0.8 and 10 m/s and a wide range of heat fluxes. Emphasis was placed on experimental accuracy and the uncertainty in the heat flux and vapour-side temperature difference were estimated to be 4 % and 15 % respectively. At low vapour velocity the heat-transfer enhancement was strongly dependent on fin height as expected, but at velocities of 2.4 m/s and above this dependence on fin height was markedly reduced. Enhancement was also found to decrease with increasing vapour velocity for all the tubes tested.
AB - New experimental data are reported for forced-convection condensation of steam on a set of four single, copper, integral-fin tubes. All tubes had a fin root diameter of 12.7 mm. The fins were rectangular in cross section with fin spacing and thickness of 1.0 mm and 0.5 mm respectively and fin heights of 0.5, 0.9, 1.3 and 1.6 mm. A plain tube of outside diameter 12.7 mm was also tested. The tests were performed at a pressure slightly above atmospheric and covered vapour velocities between 0.8 and 10 m/s and a wide range of heat fluxes. Emphasis was placed on experimental accuracy and the uncertainty in the heat flux and vapour-side temperature difference were estimated to be 4 % and 15 % respectively. At low vapour velocity the heat-transfer enhancement was strongly dependent on fin height as expected, but at velocities of 2.4 m/s and above this dependence on fin height was markedly reduced. Enhancement was also found to decrease with increasing vapour velocity for all the tubes tested.
UR - https://www.scopus.com/pages/publications/105042696950
U2 - 10.1615/IHTC13.p25.160
DO - 10.1615/IHTC13.p25.160
M3 - Conference contribution
AN - SCOPUS:105042696950
SN - 9781567002263
T3 - International Heat Transfer Conference
BT - International Heat Transfer Conference 13
PB - Begell House Inc.
T2 - 13th International Heat Transfer Conference, 2006
Y2 - 13 August 2006 through 18 August 2006
ER -